Hi Chris!
> SC Alert: CPU_FAN @ MB.P1.F0.RS has FAILED.
>
> which I know means one of the [two] heatsink/fan units has a
> failed fan. I'm using this list to reach people who may well
> understand the problem, and the solutions, and I have two questions.
>
> (1) Is this a problem? I mean, if I'm not going to be pushing
> this machine hard, do I need to worry about it?
Yes. The CPU will die. It is running too hot to work without
any CPU cooling for any length of time.
> (2) How
> _hard_ is it to replace said fan? Anyone done it?
It is easy. If you want to do it properly, you need to remove all
the dried-up thermal grease on the CPU and apply some fresh thermal
paste before you put the new fan unit on.
Regards -- Volker
--
------------------------------------------------------------------------