On Thu, Jul 06, 2006 at 02:52:53PM -0700, Garrett D'Amore wrote:
> I noticed that init on NetBSD doesn't seem to handle SIGPWR reasonably.
> This is unfortunate, because init could be used to initiate a "safe"
> shutdown, switching run-states, etc.
Yes, and the apropriate powerd script can tell it to do so.
We had a lengthy discussion about this at least once, years ago, and back
then consensus was to have powerd and it's scripts to be the sole userland
part responsible for this things.
I don't see what SIGPWR -> init would gain us.