Subject: Re: vs3100/3x SCSI broken in 2.0_BETA?
To: Manuel Bouyer <bouyer@antioche.eu.org>
From: Anders Hjalmarsson <hjalmar@hjalmar.to>
List: current-users
Date: 04/27/2004 18:15:27
>
> Can you try the attached patch ? For the problem solved in 1.102, there's no
> need to check for retry at this place (the problem was really with the bus
> reset, not the bus reset condition reported by the device).
I tried the patch on my VAXstation 3100/30 (the same one that showed offline
before) and now I get "normal" output:
scsibus0: waiting 2 seconds for devices to settle...
sd0 at scsibus0 target 0 lun 0: <DEC, RZ24 (C) DEC, 211B> disk fixed
sd0: 200 MB, 1348 cyl, 8 head, 38 sec, 512 bytes/sect x 409792 sectors
sd0: async, 8-bit transfers
sd1 at scsibus0 target 2 lun 0: <DEC, RZ24 (C) DEC, 211B> disk fixed
sd1: 200 MB, 1348 cyl, 8 head, 38 sec, 512 bytes/sect x 409792 sectors
sd1: async, 8-bit transfers
boot device: sd0
-hjalmar