Subject: Re: tlp error
To: None <netbsd-help@netbsd.org>
From: Jonathan A. Kollasch <jakollasch@mcleodusa.net>
List: netbsd-help
Date: 11/15/2004 11:29:39
On Sunday, November 14, 2004 08:49 pm, Calmin wrote:
> tlp1: receive watchdog timeout
> tlp1: receive error: CRC error
> tlp1: receive watchdog timeout
> tlp1: incoming packet spilled, resetting

What is the IC model number (21040, 21143, etc)?

I've had similar mesages on the integrated 21040 in both an AlphaStation 200 
and 255. (however 21141 and greater seem less troublesome)