NetBSD-Users archive

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index][Old Index]

Re: Perc 5/i SAS



Le 15.8.2012 20:37, Thor Lancelot Simon a écrit :
On Wed, Aug 15, 2012 at 08:29:33PM +0200, moda wrote:
Hello,

I made a simple test with a 1950 server and Perc 5/i SAS Raid Controler

Something is wrong with your test results - are you sure you didn't paste
either the NetBSD or OpenBSD iostat output twice?  They should not be
identical.

Thor


Better like this : the configuration is RAID1

Netbsd 5.1.2 x64 = 13MB/s

 tin tout  KB/t  t/s  MB/s   KB/t  t/s  MB/s  us ni sy in id
   0   61  0.00    0  0.00  63.36  223 13.78   0  0  1  0 99
   0  184  0.00    0  0.00  63.58  224 13.89   0  0  2  0 98
   0   61  0.00    0  0.00  64.00  216 13.49   0  0  2  0 98
   0   61  0.00    0  0.00  64.00  223 13.92   0  0  1  0 99

# time dd if=/dev/zero of=/tmp/16g bs=65536 count=262144
^C5755+0 records in
5754+0 records out
377094144 bytes transferred in 30.275 secs (12455628 bytes/sec)
   30.29s real     0.00s user     0.60s system

-------------------------------------------------------

OpenBSD = 105MB/s

# iostat -w 1
      tty            sd0             cd0             cpu
 tin tout  KB/t t/s MB/s   KB/t t/s MB/s  us ni sy in id
   0    3 31.77   3 0.09   0.00   0 0.00   0  0  0  0100
   0  172 32.00 3389 105.91   0.00   0 0.00   0  0 11  1 88
   0   61 32.00 3539 110.59   0.00   0 0.00   0  0 37  2 61
   0   60 32.00 3532 110.37   0.00   0 0.00   0  0  0  2 98
   0   60 32.00 3433 107.27   0.00   0 0.00   0  0 50  1 49
   0   60 32.00 3515 109.84   0.00   0 0.00   0  0  0  1 99
   0   60 32.00 3429 107.17   0.00   0 0.00   0  0 43  5 52
   0   61 32.00 3565 111.41   0.00   0 0.00   0  0  6  0 94
   0   60 32.00 3426 107.05   0.00   0 0.00   0  0 12  2 86
   0   60 32.00 3531 110.33   0.00   0 0.00   0  0 38  2 60



Home | Main Index | Thread Index | Old Index