NetBSD-Users archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index][Old Index]
Re: diagnosis for disk drive errors (zfs on cgd on sata disk)
pouya+lists.netbsd%nohup.io@localhost (Pouya Tafti) writes:
Your disk controller gives the error reason:
>[ 57131.573806] mpii0: physical device removed from slot 7
>Apart from the drive, I have also little faith in the
>backplate, cables, SAS controller (which I reflashed), RAM,
>etc., although here it looks to me like the problem could
>be somewhere between the drive and the controller.
Yes. It could be the drive itself, but I'd suspect the
backplane or cables. The PSU is also a possible candidate.