On Fri, Mar 10, 2023 at 08:53:47AM +0530, Mayuresh wrote:
> On Thu, Mar 09, 2023 at 09:34:05AM +0900, Henry wrote:
> > Because of the battery options which would allow me to do without a UPS,
>
> Hi. Curious about this usage pattern. For devices that are deployed for
> some purpose, to work without frequent manual intervention, the question
> is when would you charge the battery?
>
> Either you can keep the charger connected - which may possibly swell the
> battery soon, unless the device has some way to auto-stop charging at some
> upper threshold and auto-restart the charging only when the battery
> reaches a lower threshold.
The olimex boards have an embeeded LIPO charger, it is part of
the AXP209 PMU used on the board. You can even monitor the battery status
from NetBSD:
/home/bouyer>envstat
Current CritMax WarnMax WarnMin CritMin Unit
[axp20x0]
AC input: TRUE
AC input voltage: 4.940 V
AC input current: 0.363 A
VBUS input: FALSE
VBUS input voltage: N/A
VBUS input current: N/A
battery: TRUE
battery voltage: 4.157 V
battery current: 0.000 A
APS output voltage: 4.855 V
internal temperature: 32.200
--