Subject: Re: AlphaServer1200 scsi settle wait stalling
To: Oliver Pitterling <op@terraflux.com>
From: Manuel Bouyer <bouyer@antioche.eu.org>
List: port-alpha
Date: 12/07/2002 17:13:27
On Sat, Dec 07, 2002 at 08:08:40AM -0800, Oliver Pitterling wrote:
> Hi Manuel,
>
> The other SCSI bus goes straight into the Hot-Plug Disk Array on the right.
> Also, the cable does not appear to allow connection of the cdrom between the
> controller and array.
>
> And, yes, the scsibus1 line appears twice on the console.
This is wrong and may be the cause of the problem.
Do you have a way to send me the complete boot messages ?
setting up a serial console (if not already done) will help a lot ...
--
Manuel Bouyer <bouyer@antioche.eu.org>
NetBSD: 23 ans d'experience feront toujours la difference
--