Subject: Re: ccd/SCSI error
To: Erik Rungi <blackbox@openface.ca>
From: Jason Thorpe <thorpej@nas.nasa.gov>
List: port-i386
Date: 06/28/1999 09:37:47
On Mon, 28 Jun 1999 07:47:03 -0400 (EDT)
Erik Rungi <blackbox@openface.ca> wrote:
> I saw this on my console this morning (and its in the dmesg buffer as well).
>
> Can anyone enlighten me as to what this means:
>
> sd2(ahc0:2:0): DEFERRED ERROR, key = 0x4
> sd2(ahc0:2:0): Check Condition on CDB: 0x2a 00 00 60 a7 70 00 00 10 00
> SENSE KEY: Hardware Error
> INFO FIELD: 6624732
> ASC/ASCQ: Mechanical Positioning Error
> FRU CODE: 0x1
>
> ccd0: error 5 on component 2
>
> Does this mean the ccd failed to read/write some data, or does it mean that a
> hardware level error occured but my machine was smart enough to try doing
> whatever it needed to do again, or does it mean something else entirely?
The CCD failed to write the data, because the underlying disk failed to
write the data; if the error is recovered from, EIO isn't (supposed to be)
returned.
Looks like the disk was unable to perform a seek?
-- Jason R. Thorpe <thorpej@nas.nasa.gov>