Subject: Re: second internal hard drive on a DS5000/25
To: None <port-pmax@netbsd.org>
From: Toru Nishimura <nisimura@itc.aist-nara.ac.jp>
List: port-pmax
Date: 09/06/2000 16:03:36
[ ... invisible 2nd HD for Personal DS ... ]
> The machine in question now had two RZ25 drives, a 25MHz CPU, and 40M
> of RAM (8M onboard and 4 8M SIMMs). When the machine is powered
> on and I run cnfg 3, I get:
> ...
> DEV PID VID REV SCSI DEV
> ===== ================== ========== ====== ========
> rz1 RZ25 (C) DEC DEC 0A00 DIR
> rz2 RZ25 (C) DEC DEC 0900 DIR
[ ... but rz1 can not be probed correctly by NetBSD/pmax kernel ... ]
> Does anyone have any idea
> what might be causing the second drive to not show up?
Missing SCSI termination?
All of three my PDS configurations with single drive never have
SCSI terminating register packs, however, dual drive configuration
might be electorically sensitive in that subject.
Tohru Nishimura