Subject: Re: Can't enter DDB
To: Bob Lantz <lantz@Stanford.EDU>
From: Maciej W. Rozycki <macro@ds2.pg.gda.pl>
List: port-pmax
Date: 11/21/2001 13:17:41
On Tue, 20 Nov 2001, Maciej W. Rozycki wrote:
> I believe it's an Access.Bus feature -- the key combination gets sent as
> a separate signal that is wired to an I/O ASIC interrupt input as well
> (please someone correct me if I am wrong). Thus no -- only a MAXINE with
> an LK501 would do. Anyway it doesn't differ much from the halt button
> from the functional point of view.
A minor correction: the halt request is routed to a CPU interrupt
directly, not via the I/O ASIC. This easies keeping it unmasked a bit,
but the problems still apply.
--
+ Maciej W. Rozycki, Technical University of Gdansk, Poland +
+--------------------------------------------------------------+
+ e-mail: macro@ds2.pg.gda.pl, PGP key available +