Subject: Re: First Boot fails!
To: None <port-sparc@netbsd.org>
From: Izumi Tsutsui <tsutsui@ceres.dti.ne.jp>
List: port-sparc
Date: 06/16/2003 02:29:54
In article <20030615170946.GA21425@bseis.eis.cs.tu-bs.de>
hannken@eis.cs.tu-bs.de wrote:

> On Sat, Jun 14, 2003 at 06:08:31PM -0400, Andrew Obusek wrote:
> > esp0: identify failed, state 3, intr 0c
> > <dropping msg byte 0>esp0: unexpected disconnect; sending REQUEST SENSE
> > <dropping msg byte 0><dropping msg byte c0>esp0: unexpected disconnect;
> > sending REQUEST SENSE

> Izumi Tsutsui reported this problem using seagate drives and suggested
> to disable tagged queuing (see ESP(4)).

Tagged queuing problem on old ESP100 has been fixed in -current
and 1.6.1. It's working fine on my SS1+ and seagate drives.

But anyway sun4c machines with sw flush cache (SS1, SS1+ and IPC)
have another problem which causes ramdom segfaults (port-sparc/14180).
---
Izumi Tsutsui
tsutsui@ceres.dti.ne.jp