Subject: Re: VS3100 diag leds
To: Brian Hechinger <wonko@tmok.com>
From: Brian Chase <bdc@world.std.com>
List: port-vax
Date: 05/22/2001 17:46:14
On Tue, 22 May 2001, Brian Hechinger wrote:
> On Tue, May 22, 2001 at 06:02:18PM -0400, linc wrote:
> > OK, I have a VS3100m38 hooked to a Wyse 150 dumb term - works great..
> > What gives?
>
> i just heard back from the guy and he's got his pc hooked up to it now, so it
> must have been a funky cable, nevermind!!
Yeah, I normally just use vanilla four-wire telephone cables with the
latches cut off if I'm doing MMJ-MMJ connections between a VS3100 and a
MMJ terminal. Or if I need to go to DB-25 RS232, I get a plastic
snap-together adapter that goes from RJ45 to DB-25 and run the appropriate
wiring from the middle four RJ45 pins to the necessary DB-25 pins.
-brian.