Port-vax archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index][Old Index]
Re: About support for rtVAX300
Holm Tiffe wrote:
> Johnny Billquist wrote:
>
> > A few questions below, as I have a hard time following what you actually
> > have done...
> >
> > On 2013-01-12 23:53, Holm Tiffe wrote:
> > >[..]
> > >
> > >I'm no on that point, weher I should be able to talk with the UART.
> > >
> > >The machine boots int my (incomplete) scncnprobe().
> > >
> > >void
> > >scncnprobe(struct consdev *cn)
> > >{
> > >
> > >//static vaddr_t dz_regs;
> > >
> > > extern vaddr_t iospace;
> > > vaddr_t * du_base;
> > > int diagcons;
> > > paddr_t ioaddr = 0x20100000;
> > > extern const struct cdevsw scn_cdevsw;
> > >
> > > switch(vax_boardtype) {
> > > case VAX_BTYP_RT300:
> > > diagcons = 0;
> > > break;
> > > default:
> > > cn->cn_pri = CN_DEAD;
> > > return;
> > > }
> > > if (diagcons)
> > > cn->cn_pri = CN_REMOTE;
> > > else
> > > cn->cn_pri = CN_NORMAL;
> > > cn->cn_dev = makedev(cdevsw_lookup_major(&scn_cdevsw), diagcons);
> > > du_base = (void *)iospace;
> > > ioaccess(iospace, ioaddr, 1);
> > > du_base[0xc]=0xa;
> > > DELAY(10000);
> > > du_base[0xc]=(u_char)0x42;
> > > DELAY(10000);
> > > __asm("halt");
> > >
> > >}
> > >
> > >...and finally halts at bottom.
> > >I've used that dz_vsbus.c as example and this is the very first call
> > >to my driver.
> > >The UART in this moment should be still poper initialized from the ROM
> > >code, so writing to this Transmit buffer at 0x2010000c should print out
> > >the char 'B'.
> >
> > I assume what you see is that it comes to the halt, but nothing is
> > printed on the console, right?
> >
> > Check your assignment to iospace in your code... :-)
> > (I hope you do understand what you are doing...)
> [..]
> >
> > Yes, be more careful and observant when you write your code. :-)
> >
> > Johnny
>
Ok changing the declaration of du_base to volatile char * seems to make
that shit work:
myip: rtvax (192.168.50.20)
root addr=192.168.50.50 path=/data/home/exports/rtvax
2070940+92260=0x2105c0
BC
?06 HLT INST
PC = 800F216E
>>>
(added an 'C' in the code)
Regards,
Holm
--
Technik Service u. Handel Tiffe, www.tsht.de, Holm Tiffe,
Freiberger Straße 42, 09600 Oberschöna, USt-Id: DE253710583
www.tsht.de, info%tsht.de@localhost, Fax +49 3731 74200, Mobil: 0172 8790 741
Home |
Main Index |
Thread Index |
Old Index