On 3/22/20 6:48 PM, Maciej W. Rozycki wrote:
> NB this is the usual failure mode of the H7821 PSU used in these systems,
> which has capacitors suffering from a known issue with the quaternary
> ammonium salt system used in the electrolyte. It causes the seal to fail
> eventually and the affected capacitor to leak wreaking havoc. Thankfully
> the H7821 is mounted such that the capacitors are upside down in normal
> operation making the gravity prevent the electrolyte from interfering with
> the seal. Consequently leaks I believe only happen if a machine using an
> H7821 is stored in a different orientation, such as on its side, and not
> while in use.
>
> The capacitors I have seen fail in this PSU were actually Chemi-Con SXF
> line ones (1800µF/25V as you say) and according to my notes there ought to
> be five rather than four actually. I would highly recommend chasing the
> fifth one and replacing it too.
>
> Other reputable makes and lines of capacitors of the time also suffered
> from the said problem, e.g. I saw Nichicon PL parts leak in the H7826 PSU
> used with some DECstation 5000 machines.
Excellent information Maciej, I've made a note of this too. Thank you
for the explanation.
Of course now I remember that I've been storing probably 25
VAXstations and DECstations of that era up on their sides for twenty
years. Crap!
-Dave
--