Re: TMSCP driver



Thanks to all for your help.  I have since found that the DLT4000 drive is not supplying voltage to the terminator - not necessarily a bad thing with a short internal cable, since the host adapter is, but it indicates something else wrong on the circuit board.    The drive passes its own POST and loads a tape, so it may be minor.  (Yes, I have looked for a fuse  but don't see  one).  I am waiting for some blank tapes for the Exabyte 8200 that I have before I can test the host adapter.with it

cheers,

Nigel


Nigel Johnson, MSc., MIEEE, MCSE VE3ID/G4AJQ/VA3MCU
Amateur Radio, the origin of the open-source concept!
Skype:  TILBURY2591 nw.johnson%ieee.org@localhost



On 2021-02-02 9:57 p.m., Mark Pizzolato - Info Comm wrote:
On Tuesday, February 2, 2021 at 6:50 PM, Nigel Johnson wrote:
Does anybody know what BR level the TMSCP driver is looking for the
hardware to be at? I just found that the Dilog SQ703 is set for BR4 and that
seems too low.
BR4 on the Qbus is correct.

BR5 on a Unibus would be correct.

- Mark