Source-Changes-HG archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index][Old Index]
[src/trunk]: src/sys/dev/acpi the "Battery Present Rate" is only required to ...
details: https://anonhg.NetBSD.org/src/rev/3b79c3eb496b
branches: trunk
changeset: 751202:3b79c3eb496b
user: drochner <drochner%NetBSD.org@localhost>
date: Wed Jan 27 22:17:28 2010 +0000
description:
the "Battery Present Rate" is only required to be valid if the battery
is discharging; it might make sense when charging, but it doesn't
make sense if neither is the case -- remove a wrong assertion and
arrange the code to make this obvious
(actually, the ACPI spec says that the requirement is only for
rechargeable batteries)
diffstat:
sys/dev/acpi/acpi_bat.c | 10 +++++-----
1 files changed, 5 insertions(+), 5 deletions(-)
diffs (42 lines):
diff -r 7bea78153625 -r 3b79c3eb496b sys/dev/acpi/acpi_bat.c
--- a/sys/dev/acpi/acpi_bat.c Wed Jan 27 22:03:11 2010 +0000
+++ b/sys/dev/acpi/acpi_bat.c Wed Jan 27 22:17:28 2010 +0000
@@ -1,4 +1,4 @@
-/* $NetBSD: acpi_bat.c,v 1.78 2010/01/24 11:32:13 jruoho Exp $ */
+/* $NetBSD: acpi_bat.c,v 1.79 2010/01/27 22:17:28 drochner Exp $ */
/*-
* Copyright (c) 2003 The NetBSD Foundation, Inc.
@@ -75,7 +75,7 @@
*/
#include <sys/cdefs.h>
-__KERNEL_RCSID(0, "$NetBSD: acpi_bat.c,v 1.78 2010/01/24 11:32:13 jruoho Exp $");
+__KERNEL_RCSID(0, "$NetBSD: acpi_bat.c,v 1.79 2010/01/27 22:17:28 drochner Exp $");
#include <sys/param.h>
#include <sys/systm.h>
@@ -462,20 +462,20 @@
rv = AE_TYPE;
goto out;
}
-
- KDASSERT((uint64_t)elm[i].Integer.Value < INT_MAX);
}
- rate = elm[ACPIBAT_BST_RATE].Integer.Value;
state = elm[ACPIBAT_BST_STATE].Integer.Value;
if ((state & ACPIBAT_ST_CHARGING) != 0) {
+ /* XXX rate can be invalid */
+ rate = elm[ACPIBAT_BST_RATE].Integer.Value;
sc->sc_sensor[ACPIBAT_CHARGERATE].state = ENVSYS_SVALID;
sc->sc_sensor[ACPIBAT_CHARGERATE].value_cur = rate * 1000;
sc->sc_sensor[ACPIBAT_DISCHARGERATE].state = ENVSYS_SINVALID;
sc->sc_sensor[ACPIBAT_CHARGING].state = ENVSYS_SVALID;
sc->sc_sensor[ACPIBAT_CHARGING].value_cur = 1;
} else if ((state & ACPIBAT_ST_DISCHARGING) != 0) {
+ rate = elm[ACPIBAT_BST_RATE].Integer.Value;
sc->sc_sensor[ACPIBAT_DISCHARGERATE].state = ENVSYS_SVALID;
sc->sc_sensor[ACPIBAT_DISCHARGERATE].value_cur = rate * 1000;
sc->sc_sensor[ACPIBAT_CHARGERATE].state = ENVSYS_SINVALID;
Home |