On 2006-03-16 smb@cs.columbia.edu wrote: > > The question is this: what do you do in the interrupt handler or > timeout if you can't get the mutex? You can't sleep; there's no > process context. Only spin locks can be used. The spl calls make sure there is never contention from the same processor. Matthew Orgass darkstar@city-net.com