Re: proposal: stop using the xen_system_time timecounter in dom0



At Fri, 21 Jun 2024 08:59:01 +0200, Manuel Bouyer <bouyer%antioche.eu.org@localhost> wrote:
Subject: Re: proposal:  stop using the xen_system_time timecounter in dom0
>
> it is perfectly reliable for me. In my case I'm not sure (really)
> that other sources would be better.

I've shown clearly that it is not always reliable without (what would
otherwise be unnecessary) workarounds (dom0_vcpus_pin=true in my case,
and perhaps even with that workaround it is still not 100% reliable).

--