NetBSD-Users archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index][Old Index]
Re: APU2 routing speed NetBSD
On Tue, Dec 20, 2016 at 10:43:22AM +0100, Manuel Bouyer wrote:
> On Tue, Dec 20, 2016 at 10:00:59AM +0100, 76nemo76%gmx.ch@localhost wrote:
> > Thanks for the info. I suppose that *CSUM is the computation of
> > the checksum of packet by the card. How I Configure it in NetBSD?
>
> with ifconfig
> e.g.
> ifconfig wm0 ip4csum tcp4csum udp4csum ...
>
> >
> > Probably this should be done in "hostname.if" file, but how.
>
> in ifconfig.wm0 and ifconfig.wm1
>
> --
> Manuel Bouyer <bouyer%antioche.eu.org@localhost>
> NetBSD: 26 ans d'experience feront toujours la difference
> --
Hi,
Unfortunately the situation has not really changed after the adding
of the computation of the checksums by the card.
I have done a new test with NFS (between a Knoppix 7.2 client and a Ubuntu 16.04 server).
The results are the same: 114Mbyte/sec for OpenBSD with firewall disabled (it
is enabled by default) and 70Mbytes/sec with NetBSD.
This is annoying while I don't understand what happens. I should still make some test
with a firewall to see how the transfer speed will decrease. With the slight
firewall (1 pass, two block rules) of OpenBSD, the speed was about 90Mbytes/sec.
By the way, is the default kernel from Netbsd SMP aware?
Is a firewall enabled by default on NetBSD (like in OpenBSD)?
Would a current kernel be better?
Thanks for your help,
Best regards,
Alan
Here are the results of my test (the file copied with dd was on an NFSv4 share):
-----------------------------------------------------------------------------------
root@Microknoppix:/tmp/s/Test# time dd if=PartSave.ntfsclone.gz of=/dev/null bs=8M
2082+1 records in
2082+1 records out
17467590412 bytes (17 GB, 16 GiB) copied, 153.702 s, 114 MB/s
real 2m33.715s
user 0m0.013s
sys 0m13.807s
root@Microknoppix:/tmp/s/Test# time dd if=PartSave.ntfsclone.gz of=/dev/null bs=8M
2082+1 records in
2082+1 records out
17467590412 bytes (17 GB, 16 GiB) copied, 252.771 s, 69.1 MB/s
real 4m12.782s
user 0m0.013s
sys 0m14.010s
root@Microknoppix:/tmp/s/Test#
-----------------------------------------------------------------------------------------
Here are the configuration of the network interfaces:
-----------------------------------------------------------------------------------------
wm0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> mtu 1500
capabilities=7ff80<TSO4,IP4CSUM_Rx,IP4CSUM_Tx,TCP4CSUM_Rx>
capabilities=7ff80<TCP4CSUM_Tx,UDP4CSUM_Rx,UDP4CSUM_Tx,TCP6CSUM_Rx>
capabilities=7ff80<TCP6CSUM_Tx,UDP6CSUM_Rx,UDP6CSUM_Tx,TSO6>
enabled=7ff80<TSO4,IP4CSUM_Rx,IP4CSUM_Tx,TCP4CSUM_Rx>
enabled=7ff80<TCP4CSUM_Tx,UDP4CSUM_Rx,UDP4CSUM_Tx,TCP6CSUM_Rx>
enabled=7ff80<TCP6CSUM_Tx,UDP6CSUM_Rx,UDP6CSUM_Tx,TSO6>
ec_capabilities=7<VLAN_MTU,VLAN_HWTAGGING,JUMBO_MTU>
ec_enabled=0
address: 00:0d:b9:42:61:9c
media: Ethernet autoselect (1000baseT full-duplex,master)
status: active
inet 172.16.0.10 netmask 0xffff0000 broadcast 172.16.255.255
inet6 fe80::20d:b9ff:fe42:619c%wm0 prefixlen 64 scopeid 0x1
inet6 fd4f:bd4e:6d27:0:de0b:f387:afeb:7 prefixlen 64
inet6 2a02:168:c000:0:de0b:f387:afeb:7 prefixlen 64
wm1: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> mtu 1500
capabilities=7ff80<TSO4,IP4CSUM_Rx,IP4CSUM_Tx,TCP4CSUM_Rx>
capabilities=7ff80<TCP4CSUM_Tx,UDP4CSUM_Rx,UDP4CSUM_Tx,TCP6CSUM_Rx>
capabilities=7ff80<TCP6CSUM_Tx,UDP6CSUM_Rx,UDP6CSUM_Tx,TSO6>
enabled=7ff80<TSO4,IP4CSUM_Rx,IP4CSUM_Tx,TCP4CSUM_Rx>
enabled=7ff80<TCP4CSUM_Tx,UDP4CSUM_Rx,UDP4CSUM_Tx,TCP6CSUM_Rx>
enabled=7ff80<TCP6CSUM_Tx,UDP6CSUM_Rx,UDP6CSUM_Tx,TSO6>
ec_capabilities=7<VLAN_MTU,VLAN_HWTAGGING,JUMBO_MTU>
ec_enabled=0
address: 00:0d:b9:42:61:9d
media: Ethernet autoselect (1000baseT full-duplex)
status: active
inet 192.168.88.2 netmask 0xffffff00 broadcast 192.168.88.255
inet6 fe80::20d:b9ff:fe42:619d%wm1 prefixlen 64 scopeid 0x2
inet6 fd4f:bd4e:6d27:2:de0b:f387:afeb:2 prefixlen 64
inet6 2a02:168:c000:2:de0b:f387:afeb:2 prefixlen 64
wm2: flags=8802<BROADCAST,SIMPLEX,MULTICAST> mtu 1500
capabilities=7ff80<TSO4,IP4CSUM_Rx,IP4CSUM_Tx,TCP4CSUM_Rx>
capabilities=7ff80<TCP4CSUM_Tx,UDP4CSUM_Rx,UDP4CSUM_Tx,TCP6CSUM_Rx>
capabilities=7ff80<TCP6CSUM_Tx,UDP6CSUM_Rx,UDP6CSUM_Tx,TSO6>
enabled=0
ec_capabilities=7<VLAN_MTU,VLAN_HWTAGGING,JUMBO_MTU>
ec_enabled=0
address: 00:0d:b9:42:61:9e
media: Ethernet autoselect
status: no carrier
lo0: flags=8049<UP,LOOPBACK,RUNNING,MULTICAST> mtu 33648
inet 127.0.0.1 netmask 0xff000000
inet6 ::1 prefixlen 128
inet6 fe80::1%lo0 prefixlen 64 scopeid 0x4
-----------------------------------------------------------------------------------------
Home |
Main Index |
Thread Index |
Old Index